Pasing Grades
  • Start Selling
  • Blog
  • Contact
  • 0

    Your cart is empty!

English

  • English
  • Spanish
  • Arabic
Create Account Sign In
  • Library
    • New Prep Guides
    • Featured Prep Guides
    • Free Exam Prep Guides
    • Best sellers
  • General
  • Nursing
    • Research Paper
    • Case Study
    • Discussion Post
    • Assignment
    • Exam
    • Practice Questions and Answers
    • Test Bank
    • solutions manual
  • Accounting
    • Case Study
    • Thesis
    • Study Guide
    • Summary
    • Research Paper
    • test bank
  • English
    • Creative Writing
    • Research Paper
    • Summary
    • Rhetorics
    • Literature
    • Journal
    • Exam
    • Grammar
    • Discussion Post
    • Essay
  • Psychology
    • Hesi
    • Presentation
    • Essay
    • Summary
    • Study Guide
    • Essay
    • Solution Manual
    • Final Exam Review
    • Class Notes
    • test bank
  • Business
    • Lecture Notes
    • Solution Manual
    • Presentation
    • Business Plan
    • Class Notes
    • Experiment
    • Summary
    • Practice Questions
    • Study Guide
    • Case Study
    • test bank
    • Exam
  • More
    • Computer Science
    • Economics
    • Statistics
    • Engineering
    • Biology
    • Religious Studies
    • Physics
    • Chemistry
    • Mathematics
    • History
    • Sociology
    • Science
    • Philosophy
    • Law
  • Pages
    • About Us
    • Selling Tips
    • Delivery Policy
    • Faq
    • Privacy Policy
  • Flash Sale
  • Home
  • S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test questions and answers

S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test questions and answers

Preview page 1 Preview page 2 Preview page 3
Add To Favorites

Share this item Share this item

  • Item Details
  • Comments (0)
  • Reviews (0)
  • Contact Seller
THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE QUALIFICATIONS. - answer OWNER RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A MIN. OF __________ YEARS. - answer 3 THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY WITH REQUIREMENTS. - answer IMPAIRMENT COORDINATOR REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN ________ FLOOR(S) ARE CONSIDERED PLANNED REMOVAL FROM SERVICE. - answer 1 SHUTDOWNS AFFECTING MORE THAN _________ FLOOR(S) ARE CONSIDERED UNPLANNED OUT OF SERVICE CONDITIONS. - answer 1 NOTIFICATION TO FDNY IS NOT REQUIRED, PROVIDED SYSTEM IS RETURNED TO SERVICE WITHIN ______ HOURS. - answer 8 FOR UNPLANNED REMOVAL FROM SERVICE, THE COF HOLDER SHALL IMMEDIATELY REPORT CONDITION TO THE ___________ AND THE FIRE DEPT. - answer OWNER OF THE BUILDING IF A MINOR DEFECT IS OBSERVED, IT SHALL BE CORRECTED WITHIN _________ DAYS OR IT WILL BE CONSIDERED AN IMPAIRMENT. - answer 30 WHAT DOES "OOS" STAND FOR? - answer OUT OF SERVICE OOS SYSTEMS SHALL BE IDENTIFIED BY PLACING ________ AT FIRE DEPT. CONNECTIONS, SYS. CONTROL VALVES, AND FIRE COMMAND CENTER - answer TAGS A _______ SHALL BE REQUIRED TO POST TAGS AT MAIN CONTROL VALVE AND ANY SECTIONAL VALVES. - answer MASTER FIRE SUPPRESSION PIPING CONTRACTOR __________ SHALL BE POSTED ON THE TAG INDICATING BOTH STATIC AND FLOW PRESSURES BEFORE AND AFTER. - answer DRAIN TEST RESULTS GREEN TAGS INDICATE THAT __________. - answer NO IMPAIRMENT WAS FOUND GREEN TAGS WILL BE PLACED ON THE ____________. - answer MAIN CONTROL VALVE SYSTEMS PARTIALLY OR FULLY OUT OF SERVICE SHALL HAVE A ____________ TAG PLACED ON THE MAIN CONTROL VALVE. - answer RED A _________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO INDICATE THE SYSTEM IS FULLY OUT OF SERVICE. - answer WHITE A ________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO INDICATE THE SYSTEM IS PARTIALLY OUT OF SERVICE. - answer BLUE THE IMPAIRMENT COORDINATOR WILL NOTIFY THE ___________ CARRIER, CENTRAL STATION AND OCCUPANTS. - answer INSURANCE PRIOR TO RETURNING A SYS. TO SERVICE, THE ___________ SHALL ENSURE THAT NECESSARY TESTS AND INSPECTIONS ARE CONDUCTED. - answer IMPAIRMENT COORDINATOR GLYCERIN NOT GREATER THAN _________ PERCENT OR GLYCOL NOT GREATHER THAN ________ PERCENT SHALL BE USED TO PROTECT FROM FREEZING. - answer 50, 40 THE COF NUMBER AND SIGNATURE OF COF HOLDER SHALL BE POSTED NEAR THE ____________. - answer MAIN CONTROL VALVE __________ SHALL BE READILY AVAILABLE TO ANY REPRESENTATIVE OF THE FIRE DEPT. THESE ARE TO BE MAINTAINED ON SITE FOR 3 YEARS. - answer RECORDS FAILURE TO MAKE INSPECTIONS MAY RESULT IN __________ OF THE COF AND COURT PROCEEDINGS. - answer REVOCATION THE COF HOLDER MAY INSPECT, TEST, AND PERFORM ROUTINE MX IF THEY HOLD THE FOLLOWING CERTS: - answer REFRIGERATION OPERATING ENGINEER, HIGH PRESSURE OPERATING ENGINEER, AND NYS HIGH PRESSURE OPERATING ENGINEER. A ________ CAN INSPECT, MAINTAIN, TEST, AND REPAIR ALL FIRE STANDPIPE AND SPRINKLER SYSTEMS. - answer MASTER FIRE SUPPRESSION PIPING CONTRACTOR (MFSPC) A MASTER PLUMBER (MP) WITH COF IS LIMITED TO RESIDENTIAL OCCUPANCIES WITH _________ SPRINKLER HEADS OR LESS. - answer 30 ABOUT ______ PERCENT OF FIRES ARE EXTINGUISHED OR CONTROLLED WHEN SPRINKLERS ARE INSTALLED. - answer 96 WET PIPE SYSTEMS HAVE WATER AT A MINIMUM TEMP. OF _______ TO PREVENT THE SYSTEM FROM FREEZING. - answer 40 FAHRENHEIT __________ VALVES ARE NO LONGER PERMITTED TO BE INSTALLED. - answer COLD WEATHER ________ SYSTEMS ARE INSTALLED WHERE A WET PIPE SYSTEM CANNOT BE HEATED TO PREVENT FREEZING. - answer DRY PIPE THE DROP IN ________ CAUSES A SPECIAL DRY PIPE VALVE TO OPEN. - answer AIR PRESSURE IN BUILDINGS WHERE LIFE HAZARD IS HIGH (SCHOOLS, HOSPITALS) THE ALARM IS TRANSMITTED DIRECTLY TO THE _________. - answer FIRE DEPARTMENT DRY PIPE VALVES ARE OF A ______ DESIGN. - answer CLAPPER DRY PIPE VALVES ARE USUALLY SET AT ________ PSI ABOVE THE NORMAL TRIP LEVEL. - answer 15-20 AN ACCELERATOR AND EXHAUSTER ARE USED TO _______THE TIME TO ALLOW WATER INTO THE SYSTEM. - answer REDUCE BOTH ACCLERATOR AND EXHAUSTER ARE ACTIVATED WHEN A DROP OF _______ PSI IS DETECTED IN THE SYSTEM. - answer 2 IN A PREACTION SYSTEM, THE ___________ IS OPENED BEFORE THE SPRINKLER HEADS. - answer PREACTION VALVE PREACTION SYSTEM ALARMS ARE GIVEN AS SOON AS THE _________ IS OPENED. - answer VALVE THREE DEVICES USED TO TRIP PREACTION VALVES ARE FIXED TEMP DEVICES, RATE DEVICES, AND ___________ DEVICES. - answer COMBINATION THE _________ FEATURE SHUTS OFF WATER WHEN THE FIRE IS EXTINGUISHED AND TURNS ON AGAIN IF THE FIRE REKINDLES. - answer RECYCLING THE ________ IN THE DELUGE SYSTEM ARE OPEN AT ALL TIMES. - answer SPRINKLER HEADS _________ SYSTEMS ARE USUALLY FOUND IN BASEMENTS OR OTHER DIFFICULT TO REACH AREAS. - answer PERFORATED PIPE ________ NOZZLES ARE USED FOR TRANSFORMER VAULTS AND OTHER HAZARDOUS AREAS. - answer OPEN-FIXED EXTERIOR EXPOSURE SPRINKLERS USE OPEN SPRINKLER HEADS TO FORM A _______ ON THE WALL OF A BUILDING. - answer WATER CURTAIN _________ SYSTEMS ARE USED FOR THE PROTECTION OF SPECIAL HAZARDOUS OCCUPANCIES. - answer FOAM SUPPLY THE COF HOLDER SHALL KNOW THE LOCATION OF ALL SPRINKLER HEADS, CONTROL VALVES, SUPPLY LINES AND _________ ROOMS. - answer COMPACTOR A SIGN INDICATING THE LOCATION OF ALL _______ SHALL BE KEPT IN THE COMPACTOR ROOM. - answer CONTROL VALVES ALL INDICATING VALVES IN THE COMPACTOR SPRINKLER SYSTEM SHALL BE ________ OPEN. - answer SEALED A MINIMUM OF _________ EXTRA SPRINKLER HEADS WITH THE APPROPRIATE WRENCHES SHALL BE AVAILABLE TO REPLACED DAMAGED ONES - answer 6 THE COF HOLDER SHALL CONDUCT AN INSPECTION OF THE ENTIRE SPRINKLER SYSTEM AT LEAST __________. - answer ONCE A MONTH AUTOMATIC BALL DRIP DEVICES SHALL BE INSTALLED IN THE _________ POSITION. - answer HORIZONTAL IF THE SPRINKLER SYS. IS SUPPLIED FROM PUBLIC WATER MAIN, THE CONTROL VALVE SIGN MAY READ ________________. - answer "SHUTOFF FOR SPRINKLER SYS. LOCATED 6 FEET FROM THIS SIGN" GATE VALVES OF THE NON-INDICATING TYPE ARE CALLED ________. - answer CURB VALVES IN AN OUTSIDE STEM AND YOLK VALVE (OS&Y), VALVE POSITION IS INDICATED BY THE POSITION OF THE ____________. - answer STEM ON A POST INDICATOR VALVE (PIV), THE POSITION OF THE VALVE IS SHOWN THROUGH A ___________. - answer TELLTALE FDNY CONNECTIONS TO AUTOMATIC SPRINKLER SYSTEMS SHALL BE PAINTED ___________. - answer GREEN FDNY CONNECTIONS TO NON-AUTOMATIC SPRINKLER SYSTEMS SHALL BE PAINTED ___________. - answer SILVER FDNY CONNECTIONS TO STANDPIPE SYSTEMS SHALL BE PAINTED ____________. - answer RED FDNY CONNECTIONS TO A COMBINED STANDPIPE/SPRINKLER SYSTEM SHALL BE PAINTED ___________. - answer YELLOW FDNY CONNECTIONS SHALL BE FITTED WITH A LOWER CHECK VALVE. THIS WILL PREVENT ________ OF WATER. - answer BACKFLOW PRESSURE TANKS SHOULD BE KEPT ________ FULL AND BE MAINTAINED AT OR ABOVE ________ PSI. - answer 2/3, 75 ___________ ARE DESIGNED TO TAKE WATER FROM A SUPPLY AND DISCHARGE IT UNDER PRESSURE. - answer FIRE PUMPS AUTOMATIC FIRE PUMPS ARE USUALLY NEEDED WHERE A ___________ MAY OCCUR IMMEDIATELY. - answer HIGH WATER DEMAND WATER ALARMS SERVE AS FIRE EXTINGUISHING SYSTEMS AND SERVE AS A(N) _________. - answer AUTOMATIC FIRE ALARM. SPRINKLER SYSTEMS ARE REQUIRED TO HAVE AN APPROVED MOTOR GONG, BELL, HORN, OR ________. - answer SIREN SPRINKLERS MANUFACTURED AFTER 1/1/2000 ARE REQUIRED TO HAVE A _____________. - answer SPRINKLER IDENTIFICATION NUMBER (SIN) _________ SPRINKLERS HAVE BEEN RECALLED. - answer CYCLING SPRINKLER HEADS EXPOSED TO ___________ CONDITIONS ARE OFTEN COVERED WITH A COAT OF WAX, OR LEAD. - answer CORROSIVE AT A DISTANCE OF 4 FEET BELOW THE DEFLECTOR, THE SPRAY PATTERN COVERS A DIAMETER OF _________ FEET WHEN DISCHARGING AT 15 GPM. - answer 16 LARGE DROP SPRINKLER HEADS ARE USED TO BREAK THROUGH THE STRONG __________ OF HIGH CHALLENGE FIRES. - answer UPDRAFTS IF A FIRE HAS BEEN COMPLETELY EXTINGUISHED, THE __________ OR THEIR REPRESENTATIVE MAY CLOSE THE CONTROL VALVE. - answer BUILDING OWNER BUILD UP OF FOREIGN MATERIALS ON SPRINKLER HEADS IS COMMONLY CALLED _________. - answer LOADING SPARE SPRINKLERS SHALL BE KEPT AT THE FACILITY WHEN THE TEMPERATURE DOES NOT EXCEED _________. - answer 100 DEGREES FAHRENHEIT FACILITIES WITH LESS THAN 300 SPRINKLERS REQUIRE __________ SPARES TO BE AVAILABLE. - answer 6 FACILITIES WITH 301-1000 SPRINKLERS REQUIRE ________ SPARES TO BE AVAILABLE. - answer 12 FACILITIES WITH OVER 1000 SPRINKLERS REQUIRE ________ SPARES TO BE AVAILABLE. - answer 24

Contact the Seller

Please Sign In to contact this seller.


  • 👎  Report Copyright Violation

Frequently Asked Questions

What Do I Get When I Buy This Study Material?

+

When you buy a study material on Passing Grades, an instant download link will be sent directly to your email, giving you access to the file anytime after payment is completed.

Is Passing Grades a Trusted Platform?

+

Yes, Passing Grades is a reputable students’ marketplace with a secure payment system and reliable customer support. You can trust us to ensure a safe and seamless transaction experience.

Will I Be Stuck with a Subscription?

+

No, all purchases on Passing Grades are one-time transactions. You only pay for the notes you choose to buy, with no subscriptions or hidden fees attached.

Who Am I Buying These Study Materials From?

+

Passing Grades is a marketplace, which means you are purchasing the document from an individual vendor, not directly from us. We facilitate the payment and delivery process between you and the vendor.

Does Passing Grades Offer Free Study Materials?

+

Yes, sellers on Passing Grades have uploaded numerous free test banks, exams, practice questions, and class notes that can be downloaded at no cost.

Pasinggrades - Quality Study Materials

USD 15

    • Quality checked by Pasing Grades
    • 100% satisfaction guarantee
    • Seller: BACKTOSCHOOL
Buy PDF $15

Seller Information

BACKTOSCHOOL

Member since January 2024

  • icon
View Profile
  • total sales

    0
  • Favourites

    0
  • Comments

    0
    ( 0 Ratings )

Item Information

  • Uploaded

    04 January 2024

  • Updated

    24 November 2025

  • Category

    Engineering

  • Item Type

    exam

  • Tags

    S 12 CITYWIDE SPRINKLER SYSTEMS S12 sprinkler test questions and answers

Related Exam Prep Guides by BACKTOSCHOOL

Chapter 08: Pain Lewis: Medical-Surgical Nursing, 10th Edition with 100% correct answers
View Document

Chapter 08: Pain Lew...

  • BACKTOSCHOOL

    BACKTOSCHOOL

  • exam

Chapter 08: Pain Lewis: Medical-Surgical Nursing, 10th Edition with 100% correct answers Which quest...

15 USD

0

0

Care of the Surgical Patient nclex test questions and answers 2025/2026
View Document

Care of the Surgical...

  • BACKTOSCHOOL

    BACKTOSCHOOL

  • exam

Care of the Surgical Patient nclex test questions and answers 2025/2026 A perioperative nurse is pre...

15 USD

0

0

Surgery: Surgical Nursing Exam with Verified Solutions
View Document

Surgery: Surgical Nu...

  • BACKTOSCHOOL

    BACKTOSCHOOL

  • exam

Surgery: Surgical Nursing with verified solutions...

15 USD

0

0

Purchase

Download link will be sent to this email immediately after purchase.

IMPORTANT LINKS

  • How To Upload Class Notes
  • Selling Tips
  • Passing Grades's Study Materials
  • Scholarships for International Students 2025

POPULAR CATEGORIES

  • Law
  • Accounting
  • English
  • Psychology
  • Business
  • Nursing
  • Computer Science
  • General

View Document

  • Blog
  • Contact
  • Delivery Policy
  • Latest Scholarships Around the World
  • How to Pass Bar Exams: Passing Grades’ Strategies
  • How to Study and Pass the CPA Exam
  • All Test Banks
  • Faq
  • Copyright Claims
  • Privacy Policy
  • Terms of Use

KNOWLEDGE BASE

  • How to Write A+ Grade Good Research Paper
  • How to Manage Stress During Exam Period
  • Best Time to Study
  • How to Pass NCLEX-RN Exam
  • How To Effectively Utilize Test Banks
  • Popular Shadow Health Exam Assessments
  • Popular HESI Case Studies
  • How to Prepare for a Nursing Career
  • The Importance Of Summaries in Exam Revisvion

© 2026 Pasing Grades. All rights reserved.